Table of contents
Named Groups
Download API definition:
This API is a Technical Preview and is available for testing purposes only. Do not use in production.
GET https://api.bentley.com/named-groups/{groupId}

Retrieves a group.

Group Query

The query parameter of a Group must be a valid ECSQL query.

If a valid ECSQL query is given and the selected class is bis.Element, or if it is a descendant of the class bis.Element, the only required column is ECInstanceId. However, it is recommended to always select at least ECInstanceId and ECClassId columns.

  • SELECT * FROM bis.Element is a valid query
  • Assuming that class Building.Beam is a descendant of the class bis.Element, the query SELECT * FROM Building.Beam is a valid query
  • SELECT ECInstanceId, ECClassId FROM bis.Element is a valid query
  • Assuming that class Building.Beam is a descendant of the class bis.Element, the query SELECT ECInstanceId, ECClassId FROM Building.Beam is valid
  • SELECT ECClassId FROM bis.Element is not a valid query because ECInstanceId column is missing
  • Assuming that class Building.Beam is a descendant of the class bis.Element, the query SELECT ECClassId FROM Building.Beam is not valid because ECInstanceId column is missing
  • Assuming that Building.BeamAspect is an aspect, the query SELECT A.ECInstanceId ECInstanceId FROM bis.Element E JOIN Building.BeamAspect A ON A.Element.id = E.ECInstanceId is not valid because the selected ECInstanceId is of the aspect, not the element
  • Assuming that Building.BeamAspect is an aspect, the query SELECT Element.id FROM Building.BeamAspect is not valid because the selected column's name is not ECInstanceId
  • Assuming that Building.BeamAspect is an aspect, the query SELECT Element.id ECInstanceId FROM Building.BeamAspect is valid

In all other cases the provided ECSQL query is required to select ECInstanceId and ECClassId. If ECClassId is omitted, the service assumes that query selects elements from the bis.Element class or its descendants. In some cases the results might be unexpected, e.g., you assume that you are querying bis.ElementAspect but you only select ECInstanceId so the service only selects the elements that have a matching ECInstanceId. Because of this it is always recommended to select both ECInstanceId and ECClassId.

Authentication

Requires Authorization header with valid Bearer token for scope itwin-platform.

For more documentation on authorization and how to get access token visit OAUTH2 Authorization page.

Authorization

User must have insights_view permission(s) assigned at the iTwin level.

Alternatively the user should be an Organization Administrator for the Organization that owns a given iTwin or iModel.

An Organization Administrator must have at least one of the following roles assigned in User Management: Account Administrator, Co-Administrator, or CONNECT Services Administrator. For more information about User Management please visit our Bentley Communities Licensing, Cloud, and Web Services wiki page.

Rate limits

All iTwin Platform API operations have a rate limit. For more documentation on that visit Rate limits and quotas page.

Request parameters

Name
Required?
Description
groupId
Yes

The group Id.

Request headers

Name
Required?
Description
Authorization
Yes

OAuth access token with itwin-platform scope

Accept
Yes

Setting to application/vnd.bentley.itwin-platform.v1+json is recommended.

Response 200 OK

OK

json
{
    "group": {
        "id": "08f252c4-ee78-4e2b-9280-f7365400b932",
        "displayName": "PhysicalElements",
        "description": "A group of physical elements",
        "query": "SELECT ECInstanceId, ECClassId FROM BisCore.PhysicalElement",
        "metadata": [{
                "key": "key1",
                "value": "value1"
            },
            {
                "key": "key2",
                "value": "value2"
            }
        ],
        "createdDateTime": "2021-09-03T10:48:45+00:00",
        "modifiedDateTime": "2022-01-10T13:44:56+00:00",
        "_links": {
            "iTwin": {
                "href": "https://api.bentley.com/itwins/3fa85f64-5717-4562-b3fc-2c963f66afa6"
            }
        }
    }
}

Response 401 Unauthorized

This response indicates that request lacks valid authentication credentials. Access token might not been provided, issued by the wrong issuer, does not have required scopes or request headers were malformed.

json
{
    "error": {
        "code": "HeaderNotFound",
        "message": "Header Authorization was not found in the request. Access denied."
    }
}

Response 404 Not Found

Specified resource was not found.

json
{
    "error": {
        "code": "GroupNotFound",
        "message": "Requested Group is not available.",
        "target": "groupId"
    }
}

Response 429 Too many requests

This response indicates that the client sent more requests than allowed by this API for the current tier of the client.

json
{
    "error": {
        "code": "RateLimitExceeded",
        "message": "The client sent more requests than allowed by this API for the current tier of the client."
    }
}

Response headers

Name
Description
retry-after

Number of seconds to wait until client is allowed to make more requests.

Group Metadata Entry

Name
Type
Description
key
String

Keys must be unique within the Metadata array.

value
String, null

Group Links

Hyperlinks to related data which complements this entity.

Name
Type
Description
iTwin

Link to retrieve the related iTwin.

Group

A group is a collection of design elements from an iModel represented by an ECSQL query.

Name
Type
Description
id
String

The group Id.

displayName
String

Name of the group.

description
String

Description of the group. The default value is empty string.

query
String

An ECSQL query that represents a collection of iModel elements.

metadata

An array of unique key value pairs.

createdDateTime
Date-time

Date when the named group was created.

modifiedDateTime
Date-time

Date when the named group was modified.

_links

Contains contextual hyperlinks to related data.

Group response

Container for a group object.

Name
Type
Description
group

Group properties.

Link

Hyperlink container.

Name
Type
Description
href
String

Hyperlink to the specific entity.

Error

Contains error information.

Name
Type
Description
code
String

One of a server-defined set of error codes.

message
String

A human-readable representation of the error.

target
String, null

The target of the error.

Error Response

Gives details for an error that occurred while handling the request. Note that clients MUST NOT assume that every failed request will produce an object of this schema, or that all of the properties in the response will be non-null, as the error may have prevented this response from being constructed.

Name
Type
Description
error

Error information.

Was this page helpful?